FIEM

DESCRIPTION

Designed to attenuate railway perturbations

In order to avoid harmonic perturbations, Zigor Corporation has created the FAP (Passive harmonic filter) to fulfill your needs, offering you a wide range of harmonic filters.
FAP aims to attenuate the harmonic components we can find in the network of supply. Our solution consist on deriving the harmonic components generated by a charge towards the filter and keep the network clean for the customers.

 


FEATURES

General technical features
g

Accuracy of output voltage + 2% - over 95 performance
Stabilization of the input voltage overvoltage and undervoltage
Overload permissible to 1000%
Voltage range of standard input of 10%, 15%, 20%, 30%
Correction rate 12 v / sec
Performance over 95%
Quiet operation, less than 30 db
Working frequency 45-65 Hz
Temperature -10 º / + 45 º
Maximum working height 2500 mts
Protection circuit breaker / fuse
Digital instrument for pressure reading

ADVANTAGES

Advantages of the product

  • Protection of installations subject to transient
  • Virtually unlimited number of operations
  • Parallel
  • No harmonic distortion.
  • Increased reliability in railways
  • Wide range of power
  • Improves power quality
  • High stability
  • High overload capacity
  • Absorption of energy pulses from Vn
  • Robustness

APPLICATIONS

Industrial use:

  • Telecommunications
  • Railway

DOWNLOADS

Documents

       Data Sheet

Software


Solicitar información Request information


FAP

DESCRIPTION

Designed to attenuate railway perturbations

In order to avoid harmonic perturbations, Zigor Corporation has created the FAP(Passive harmonic filter) to fulfill your needs, offering you a wide range of harmonic filters.
FAP aims to attenuate the harmonic components we can find in the network of supply. Our solution consist on deriving the harmonic components generated by a charge towards the filter and keep the network clean for the customers.

FEATURES

 

Advantages of the product

Potencia: 6,25,50,75,100,150,200,250 KVapor ventilación forzada
Temperatura ambiente comprendida entre 0ºC +45ºC
Humedad relativa comprendida entre 5% y 85%
Altitud máxima de trabajo 2.500 mts
Altitud máxima de trabajo 2.500 mts
Amplio margen tensión de entrada
Refrigeración
Sobre carga admisible 50% durante 1 minuto

 

ADVANTAGES

Advantages of the product

  • Evita perturbaciones de armónicos
  • Potencia: de 6 a 250 KVa
  • Aumento de la fiabilidad en líneas ferroviarias
  • Amplia gama de potencia
  • Mejora la calidad del suministro eléctrico
  • Alta estabilidad
  • Gran capacidad de sobrecarga
  • Absorción de impulsos de energía a partir de Vn
  • Robustez mecánica

APPLICATIONS

Industrial use:

  • Telecommunications
  • Railway

DOWNLOADS

Documents

Data sheet FAP

Software

 


FEATURES

General technical features

Power: KVapor 6,25,50,75,100,150,200,250 forced ventilation
Ambient temperature between 0 º C +45 º C
Relative humidity between 5% and 85%
Altitude 2500 m Maximum Operating
Wide input voltage range
Refrigeration
About 50% load capacity for 1 minute
 

ADVANTAGES

Advantages of the product

  • Avoid harmonic disturbances
  • Power: 6 to 250 KVA
  • Increased reliability in railways
  • Wide range of power
  • Improves power quality
  • High stability
  • High overload capacity
  • Absorption of energy pulses from Vn
  • Robustness

APPLICATIONS

Industrial use:

  • Telecommunications
  • Railway

DOWNLOADS

Documents

        Data Sheet

Software




Solicitar información Request information