DESCRIPTION


Range of single hybrid inverters for Batteries and Grid or Emergency Generator

The range of HIS hybrid inverters is designed to meet power requirements in locations not covered by the grid or where electricity is very expensive. The main feature of hybrid HIS/HIT inverters is that they are capable of generating electricity from Solar and Wind resources, from Batteries, from the Grid or Emergency Generator, in a controlled manner.


FEATURES

General technical features

Grid or Emergency Generators Input
Wind Turbine and PV field compatible through external battery charge regulator
Back-up battery
Very low harmonic distortion THD< 3%
Monitoring from the unit with LCD
Galvanic isolation via transformer
IP21 protection level
Protection against: Inverse polarisations, short circuits, overvoltages, isolation failure with relay output
As back-up or for clients with high power availability requirements: Telecom installations, IT installations
ECO mode available: inverter will not work if there´s no consumption
Output to start external emergency Generation

ADVANTAGES

Advantages of the product

Hybridizations:

  • Solar
  • Wind
  • Grid
  • Emergency generators
  • Batteries

MODELS


HIS 1.2 KVA  (800W)
HIS  2.4 KVA  (1600W)
HIS  3.6 KVA  (2400W)
HIS 5 KVA  (4000W)
HIS 6 KVA  (6000W)
HIS 8 KVA  (8000W)

APPLICATIONS


Hybrid generation plants for self-consumption and/or grid

DOWNLOADS

Documents

Data sheet

Software


Request information

 

Hybrid inverter HIS Compact

DESCRIPTION


Single-phase modular hybrid inverter (for Solar & Wind generation, Batteries and Grid or Generator)

The HIS Compact series has been designed to provide Power Supply for those applications where accessibility to grid or cost of electricity is a big issue:

  • Off-grid areas
  • Rural electrification
  • Electricity provided by Diesel Generators

The main feature of Zigor HIS Compact series of Hybrid Inverters is the capability to manage energy from various and different sources like PV Field, wind Turbines, Batteries, Diesel Generator and/or Grid.
In addition to this, the HIS Compact Hybrid Systems are able to accommodate the energy from various sources while controlling all of them through its unique management system.
The Zigor HIS Compact series of Hybrid Inverters have a modular and scalable concept where it is very easy to increase the capability by increasing the size of the PV field, the number of Wind Turbines, the power of AC input and/or the size of the battery bank.

FEATURES

General technical features

AC input: Grid or Genset
Wind Turbine and PV field controlled by dedicated internal Power module
Back-up battery
Range of input DC voltages (120-500 VDC) for PV field & wind turbines
Maximum power point tracking (MPPT) for renewable inputs
High energy efficiency MPPT > 99%
Very low harmonic distortion THD < %3
Monitoring from the unit with LCD
Galvanic isolation via transformer
IP21 protection level
Protection against: Inverse polarity, short circuits, overvoltages, isolation failure with relay output
Web server through Ethernet communication port for full access to HIS Compact System
Easy access through any web browser
Modular and scalable concept to increase future increases of power demand

MODELS

  • HIS Compact 4
  • HIS Compact 5
  • HIS Compact 7

APPLICATIONS

  • Hybrid generation
  • Energy saving
  • Telecom back-up
  • Wind energy

DOWNLOADS

Documents

Data sheet

Software


Request information




Hybrid Inverter HITC

DESCRIPTION


Three-phase hybrid inverter
(for solar or wind generation, batteries and grid or emergency)


The range of HITC hybrid inverters is designed to meet power requirements in locations not covered by the grid, hybrid rural electrification and distributed generation. The main feature of hybrid HITC inverters is that they are capable of generating electricity from Solar or Wind resources, from Batteries, from the Grid or Genset.
Zigor three-phase HITC hybrid inverters have been designed to add energy from several different sources while controlling all of them from a unique management system.



FEATURES

General technical features

Grid or Genset
Wind Turbine or PV field input through internal regulator
Back-up battery
Easy access through any web browser
Range of input DC voltages (450-700 VDC) for solar panels
Maximum power point tracking (MPPT) for solar panels
High energy efficiency MPPT > 99%
Very low harmonic distortion THD< 3%
Monitoring from the unit with LCD
Galvanic isolation via transformer
Strings Currents monitoring (option) for solar panels
IP21 protection level
Protection against: Inverse polarity, short circuits, overvoltages, isolation failure with relay output
Webserver program on PC for parameter display, data logging
Webserver program on PC for full access to HIT inverter data
Hybrid mains connection consumption points with limited power capacity or in which energy saving is a necessity
As back-up or for clients with high power availability requirements: Telecom installations, IT installations

ADVANTAGES

Advantages of the product

Hybrid:

  • Pv field
  • Wind turbine
  • Grid
  • Gen set
  • Batteries

APPLICATIONS

  • Hybrid generation
  • Energy saving
  • Telecom back up
  • Wind energy

MODELS

  • HITC 30
  • HITC 50
  • HITC 100

DOWNLOADS



Documents

Data sheet

Software


Request information


Hybrid Inverter HITD

DESCRIPTION


Hybrid Inverters for Distributed Micro-Grid Applications and Rural Electrification

In order to attend the growing demand for Rural Electrification and Distributed Generation based on Hybridizing renewable and fossil power sources, Zigor has developed a range of Hybrid Inverters for medium and high power solutions, covering from 150kVA to 1800kVA and based on two different topologies: HITC (for small mini-grid and centralized systems) and HITD for those installations where it is more suitable to distribute the Generations Resources along the micro-grid. The Hybrid Inverter Range HITD has been specially designed to build distributed hybrid micro-grid, allowing sharing the electricity generation from several different sources based on renewable as well as other generating or storage sources.

The Hybrid Inverter Range HITD can also be connected to Fuel Generators so that avoids any blackout in the micro-grid in case the renewable generation cannot cover the load demand.

The Hybrid Inverter Range HITD is also capable to be connected to existing distribution grid. In these cases, the HITD Inverters will manage the energy flow between the micro-grid and the Distribution Grid. This functionality makes possible the energy return to the Distribution Grid when the generation exceeds the consumption as well as to work autonomously even if the Distribution Grid is not available. Additionally, the HITD Inverters can be installed with both Distribution Grid and Emergency Fuel Generator, being the HITD capable of selecting the Generation Source.

FEATURES



General technical features

 

Hybrid System that allows the integration of different generation sources along the micro-grid, assuring the stability of the micro-grid either connected or isolated from a Distribution Grid
Nominal Power from 150 KVA to 1800 KVA (based on inverter modules of 150 KVA)
Compatible with the existing protection Systems already installed
Minimum Investment requirements and reduced operating costs
Maximum strength of the system
Compatible with other emergency generation Systems, like Generation Sets.
Allows the micro-grid Management through TCP/IP
Digital Management System DSP
Optional Air-conditioning for the battery cabinet
Charger Max. current: 200A at 672Vdc per 150kW module
The HITD Hybrid Inverters are capable to discriminate whether any disturbance comes from the grid or from the load, staying on by-pass in case the disturbance is produced by the load

> The HITD Hybrid Inverters consists of the following five basic systems

  • Generation System (Hybrid Inverter HITD)
  • Energy Storage System (Battery)
  • Regulation and Control System (CONTROL V/F)
  • Monitoring and Management System (SCADA)
  • Additionally, the Hybrid Inverter HITD architecture allows the integration of PV Solar, Wind and Battery Generation Systems from ZIGOR: Solar Inverter, BATGEN, WINDZET.

ADVANTAGES


Advantages of the product

Hybridization

  • Solar
  • Wind power
  • Mains
  • Gensets
  • Batteries

APPLICATIONS

  • Hybrid generation
  • Energy saving
  • Telecom back up

MODELS

  • HITD 150
  • HITD 300
  • HITD 450
  • HITD 600
  • HITD 750
  • HITD 900
  • HITD 1050
  • HITD 1200
  • HITD 1350
  • HITD 1500
  • HITD 1650
  • HITD 1800

ARCHITECTURE

> The HITD Architecture admits the following operation modes, always assuring the energy demand of the load:

MONG: On-grid mode: micro-grid connected to a Distribution Grid

+R: Integrated Renewable Generation Sources

+FH2: Integrated Generation Systems

+ADM: Active Management of generation/demand

 

MOFG: OFF-grid mode: micro-grid isolated from Distribution Grid

+R: Integrated Renewable Generation Sources

+FH2: Integrated Generation Systems

+ADM: Active Management of generation/demand

 

MNET: Hybrid Mode: bidirectional energy flow between Distribution Grid and Micro-grid

+R: Integrated Renewable Generation Sources

+FH2: Integrated Generation Systems

+ADM: Active Management of generation/demand